High Efficiency Industrial Water Cooled Scroll Chiller

 The High Efficiency Industrial Water Cooled Scroll Chiller cooling capacity from 9KW to 120KW. This series units integrates the characteristics of many other products, using imported full-closed scroll compressors, supplemented by high-efficiency heat exchangers and adopts microcomputer controllers, which makes the unit compact, reasonable layout, convenient to use and maintain. It is automatically adjusted according to load changes and is more energy efficient.


Features of Water Cooled Scroll Chiller:

1. Energy with high efficient

2. Operation noise and vibration is low

3. No friction loss

4. Low starting current

5. High system sustainability

6. Environmental protection


Safety system:

1 Compressor reverse protective

2 Freeze protector protective

3 Refrigerant safety valve

4 Buzzer

5 High-pressure gauge and Low-pressure gauge

6 Power phase failure protector

7 Coil over-heat protector

8 Temperature auto-switch

9 Refrigerant shortage protective

Box type water cooled scroll industrial chiller(R-22)
ModelHTB-9SHTB-15SHTB-23SHTB-30SHTB-35SHTB-45SHTB-46SHTB-60SHTB-90SHTB-120S
Cooling
Capacity
KW8.51523.230.1354546.460.290.3120.4
Kcal/Hr73101290019952258863010038700399045177277658103544
RT2.424.266.68.569.9512.7913.1917.1225.6834.23
Power50HZ3P-380V-50HZ
ComprosserModeFull closed high efficiency flexible scroll compressor
Input power(KW)1.973.454.946.57.4109.881319.526
Rated load current(A)3.98.29.812.613.72119.625.237.850.4
Wiring specification446661010162525
Add unloading way0,100%0,50%,100%0,33%,66%,
100%
0,25%,50%,
75%,100%
CondensorCooling water temp(℃)Inlet temp 30℃/outlet temp 35℃
Cooling water flow(m³/h)1.833.234.996.477.539.689.9812.9419.4125.89
Waterpipe diameter(DN)32324040405050506580
EvaporaterFreeze water temp(℃)Inlet temp 12℃/outlet temp 7℃
Freeze water flow(m³/h)1.462.583.995.186.027.747.9810.3515.5320.71
Waterpipe diameter(DN)32323240405050506580
SafeguardWater pump protection chain, electric leakage protection, overload protection, overpressure, the power reverse phase, open phase protection, abnormal refrigerant protection, exhaust temperature protection, Lack of water protection, etc.
SizeL(mm)980121012501250140014001500164019002500
W(mm)650650700700700700700700850800
H(mm)1080108011001100110011001100110012501250
Units WeightKg210240300320340370440560630720